PLY-SM SERIES

Series
Catalogue
Add to Cart Add to cart

Features

3D Sensor

Auto Fan Speed Mode

Auto Restart

Bacteria & Mold-resistant Filter

Long life Filter

Self-Diagnostic Function

Technical Specifications

Models PLY-SM18HA PLY-SM24HA PLY-SM30HA PLY-SM36HA PLY-SM48HA
Cooling Capacity - Rated (Min-Max) kW 5.3 (2.80 - 5.30) 7.1 (2.90 - 7.10) 8.8 (3.80 - 8.80) 10.6 (4.00 - 10.60) 14.1 (7.00 - 14.10)
Total input kW 1.52 2.15 2.48 3.45 5.8
ISEER W/W 4.74 4.71 4.72 3.9 3.7
Indoor unit Model name PLY-SM18HA-DA PLY-SM24HA-DA PLY-SM30HA-DA PLY-SM36HA-DA PLY-SM48HA-DA
Power supply 1Phase 220-240V 50Hz 1Phase 220-240V 50Hz 1Phase 220-240V 50Hz 1Phase 220-240V 50Hz 1Phase 220-240V 50Hz
External finish Munsell 1.0Y 9.2/0.2 Munsell 1.0Y 9.2/0.2 Munsell 1.0Y 9.2/0.2 Munsell 1.0Y 9.2/0.2 Munsell 1.0Y 9.2/0.2
Airflow (low-med1-med2-High) CFM 530-565-636-706 600-636-706-777 706-812-918-1059 742-883-989-1095 777-953-1130-1307
External static pressure Pa 0 (direct blow) 0 (direct blow) 0 (direct blow) 0 (direct blow) 0 (direct blow)
Operation control and thermostat Cordless Remote controller & built-in
Airflow (low-med1-med2-High) dB (A) 25-27-30-32 28-30-32-35 31-34-37-41 32-37-41-43 34-39-43-47
Unit drain pipe mm 32 32 32 32 32
Dimensions (panel) W mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)
D mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)
H mm 258 (35) 258 (35) 298 (35) 298 (35) 298 (35)
Weight (panel) kg 19 (5) 21 (5) 23 (5) 26 (5) 26 (5)
Outdoor unit Model name SUY-SM18VA-DA SUY-SM24VA-DA SUY-SM30VA-DA PUY-SM36YKA-DA PUY-SM48YKA-DA
Power supply 1Phase 220-240V 50Hz 3Phase 380-415V 50Hz
External finish Munsell 3.0Y 7.8/1.1 Munsell 3.0Y 7.8/1.1 Munsell 3.0Y 7.8/1.1 Munsell 3.0Y 7.8/1.1 Munsell 3.0Y 7.8/1.1
Refrigerant (R32) control Linear expansion valve
Airflow   CFM 1275 1285 2239 2648 3143
Noise level dB (A) 47 52 54 52 56
Dimensions W mm 800 800 840 1050 1050
D mm 285 285 330 330 330
H mm 550 714 880 981 981
Weight kg 32 38 47 67 67
Max. height difference m 20 20 30 30 30
Max. piping length m 35 35 50 50 50
Pipe size Liquid mm 6.35 9.52 9.52 9.52 9.52
Gas mm 12.7 15.88 15.88 15.88 15.88
BEE Star Rating 3 3 3 4 3
Operating Range Upper limit (CDB) 52 52 52 52 52
Lower limit (CDB) 18 18 18 18 18
      MRP 105400 115200 133700 168900 217400

 

•Rating conditions: Cooling - Indoor: 27°C (DST), 19°C , Outdoor: 35°C (DBT)                                
•Rating conditions Cooling - Indoor: 27°C(80°F)DB,19°C(66°F)W13. Outdoor: 35°C(95°F)DB                                
•Refrigerant piping length (one-way): 7.5m(2511)                                
- Total input based on the indicated voltage (indoor/outdoor): 1 ph 230V 50Hz, 3ph 400V 50Hz                                
- The sound pressure meaurement is conducted in an anechoic chamber under the test conditions of Japanese industrial Standards.                                
•The actual sound level depends on the design and appropriate set up of duct work, distance from the unit and acoustic environment                                 
- Measured with a 2.Om. Air outlet duct and 1.0m. Air inlet duct attached Measured point 1.5m. Below the unit.                                
•Rated external static pressure mode is shown with < >.                                
 