PMY-SM SERIES

Series
Add to Cart Add to cart

Features

Auto Restart

Filter Check Signal

High Ceiling Mode

Horizontal Vane swing

Long life Filter

Low Ceiling Mode

OnOff Operation Timer

Self-Diagnostic Function

Vertical Vane swing

Technical Specifications

Models PMY-SM18FA PMY-SM24FA PMY-SM30FA
Cooling Capacity - Rated (Min-Max) kW 5.3 (2.80 - 5.30) 7.1 (2.90 - 7.10) 8.8 (3.80 - 8.80)
Total input kW 1.64 2.29 2.66
ISEER W/W 4.3 4.3 4.3
Indoor unit Model name PMY-SM18FA-DA PMY-SM24FA-DA PMY-SM30FA-DA
Power supply 1Phase 220-240V 50Hz
External finish Munsell 6.4Y 8.9/0.4
Airflow (low-med1-med2-High) CFM 388-459-565-671 494-600-706-848 530-600-706-848
External static pressure Pa 0 (direct blow)
Operation control and thermostat Cordless Remote controller & built-in
Airflow (low-med1-med2-High) dB (A) 36-41-45-50 36-40-44-50 40-43-47-50
Unit drain pipe mm 32 32 32
Dimensions (panel) W mm 1112 (1340) 1112 (1340) 1112 (1340)
D mm 724 (800) 724 (800) 724 (800)
H mm 225 (20) 225 (20) 225 (20)
Weight (panel) kg 27 (6.5) 28 (6.5) 29 (6.5)
Outdoor unit Model name SUY-SM18VAB-DA SUY-SM24VAB-DA SUY-SM30VAB-DA
Power supply 1Phase 220-240V 50Hz
External finish Munsell 3.0Y 7.8/1.1 Munsell 3.0Y 7.8/1.1 Munsell 3.0Y 7.8/1.1
Refrigerant (R32) control Linear expansion valve
Airflow   CFM 1275 1285 2239
Noise level dB (A) 47 52 54
Dimensions W mm 800 800 840
D mm 285 285 330
H mm 550 714 880
Weight kg 32 38 47
Max. height difference m 20 20 30
Max. piping length m 35 35 50
Pipe size Liquid mm 6.35 9.52 9.52
Gas mm 12.7 15.88 15.88
BEE Star Rating 3 3 3
Operating Range Upper limit (CDB) 52 52 52
Lower limit (CDB) 18 18 18
      MRP 131000 136000 165000

 

•Rating conditions: Cooling - Indoor: 27°C (DST), 19°C , Outdoor: 35°C (DBT)                        
•Rating conditions Cooling - Indoor: 27°C(80°F)DB,19°C(66°F)W13. Outdoor: 35°C(95°F)DB                        
•Refrigerant piping length (one-way): 7.5m(2511)                        
- Total input based on the indicated voltage (indoor/outdoor): 1 ph 230V 50Hz, 3ph 400V 50Hz                        
- The sound pressure meaurement is conducted in an anechoic chamber under the test conditions of Japanese industrial Standards.                        
•The actual sound level depends on the design and appropriate set up of duct work, distance from the unit and acoustic environment                         
- Measured with a 2.Om. Air outlet duct and 1.0m. Air inlet duct attached Measured point 1.5m. Below the unit.                        
•Rated external static pressure mode is shown with < >.                        
 