Air Conditioning Systems

S Series Heat Pump

Total Capacity / Model Name

Technical Specifications

Model Name PUMY-SP100VKM PUMY-SP125VKM PUMY-SP140VKM
Power Source 1-Phase, 220/230/240 V, 50Hz; 1-phase 220 V, 60Hz
Cooling Capacity(Nominal) kW 11.20 14.00 15.50
Btu 38214 47768 52886
  Power Input kW 2.78 3.84 4.70
  Current Input A 12.89-12.33-11.82, 12.89 17.81-17.04-16.33, 17.81 21.80-20.85-19.98, 21.80
  EER kW/kW 4.03 3.65 3.30
Temp. range of cooling Indoor W.B. 15 to 24 C (59 to 75 F)
Outdoor D.B. -5 to 52 C (23 to 126 F)
Heating Capacity(Nominal) kW 12.5 16.0 16.5
Btu 42650 54592 56298
  Power Input kW 2.58 3.90 4.02
  Current Input A 11.97-11.45-10.97,11.97 18.09-17.30-16.58,18.09 18.65-17.83-17.09, 18.65
  COP kW/kW 4.84 4.10 4.10
Temp. range of cooling Indoor W.B. 15 to 27°C (59 to 81°F)
Outdoor D.B. -20 to 15°C (-4 to 59°F)
Indoor unit connectable Total capacity 50 to 130% of outdoor unit capacity
Model/Quantity CITY MULTI 15–125/7 15–140/10 15–140/12
Sound pressure level(Cooling/Heating)
(measured in anechoic room)
dB(A) 51/54 53/56 54/56
Refrigerant piping diameter Liquid pipe mm(in.) 9.52(3/8)
Gas pipe mm(in.) 15.88(5/8)
FAN Type x Quantity Propeller Fan × 1
Airflow rate m3/min 75 81
L/s 1,283 1,383
cfm 2,791 2,931
Motor output kW 0.20 x 1
Compressor Type x Quantity Twin rotary hermetic compressor × 1
Starting method Inverter
Motor output kW 2.7 3.5 3.7
External finish Galvanized Steel Sheet Munsell No. 3Y 7.8/1.1
External Dimension HxWxD mm 981 × 1050 × 330 (+25)
in. 38-5/8 × 41-3/8 × 13 (+1)
Protection devices High pressure protection High pressure switch
Inverter circuit
(COMP./FAN)
Overcurrent detection, Overheat detection (Heat Sink thermistor)
Compressor Compressor thermistor, Overcurrent detection
Fan motor Overheating, Voltage protection
Refrigerant Type x original charge R410A 3.5kg
Net weight kg/lbs 93 (205) *7
Heat Exchanger Cross Fin and Copper tube
Defrosting method Reversed refrigerant circuit
Optional parts Joint: CMY-Y62-G-E, Header: CMY-Y64/68-G-E, Air protect guide:PAC-SH95AG-E
  • *1, *2 Nominal conditions
  •   Indoor Outdoor Pipe length Level difference
    Cooling 27ºC DB/19ºC WB
    (81ºF DB/66ºF WB)
    35ºC DB(95ºF DB) 7.5 m (24-9/16 ft) 0m (0ft.)
    Heating 20ºC DB(68ºF DB) 7ºC DB/6ºC WB(45ºF DB/43ºF WB) 7.5 m (24-9/16 ft) 0m (0ft.)
  • *3 10 to 52:, when connecting following models: PKFY-P15/20/25VBM, PFFY-P20/25/32VLE(R)M, PFFY-P20/25/32VKM, and M-Series, S-Series, and P-Series type indoor unit with branch box, M-Series type indoor unit with connection kit.
  • *4 -15 to 52:, when using an optional air protect guide [PAC-SH95AG-E]. However, this condition does not apply to the indoor unit listed in*3.
  • *5 Cooling mode/Heating mode
  • *6 External static pressure option is available (30 Pa/3.1 mmH2O).
  • *7 94 (207), for PUMY-SP100/125/140VKM-BS. 95 (209), for PUMY-SP100/125/140YKM-BS.
  • *Nominal condition *1,*2 are subject to ISO 15042.
  • *Due to continuing improvement, above specification may be subject to change without notice.
  • *This unit cannot be connected with the PFFY-YM-E or PFFY-YMH-E.